Construction Of Process Flow Model Of Air Separation Unit

Jun 27, 2025

Leave a message

1.1 Process flow
A gas production plant uses a 60,000 m3/h cryogenic air separation unit. In the actual production process, air enters the distillation system through the compression system, precooling and expansion system to achieve gas separation. This paper mainly analyzes the nitrogen production process, and its production process flow is as follows:
1) The air passes through the filter and enters the air compressor. The compressed air is diverted through the plate-fin heat exchanger, one part enters the next-stage gas compression system, and the other part exchanges heat with the cooling medium and enters the distillation tower;
2) The air flow rate entering the next-stage gas compression system is about 5,000 kmol/h. This part of the gas enters the expander after heat exchange, and the temperature is about -120 ℃. After that, it is depressurized by the expander, the pressure is about 0.14 MPa, and heat exchange is performed, and the temperature is reduced to about -170 ℃
Enter the distillation tower;
3) The distillation tower is divided into two parts, the upper and lower parts, which are independent of each other and connected to each other through valves and pipelines. The upper tower is a low-pressure tower with a pressure of about 140 kPa, and the lower tower is a high-pressure tower with a pressure of 550 kPa The gas after heat exchange and the gas from the expander are respectively sent back to the middle and bottom of the lower tower of the distillation tower. The gas is partially converted into liquid nitrogen through the top condenser and stored in the liquid nitrogen tank, and the other part enters the upper tower for further distillation.


1.2 Construction of process flow model


It can be seen from the above air separation process that the actual production process includes compression, expansion, separation and other processes. When using Aspen Plus software for process simulation, the modules and functions used are as follows:
1) The air compressor uses the COMPR-Icon2 module;
2) The expander uses the COMPR-Icon3 module;
3) The heat exchanger uses the HEATX module;
4) The distillation tower uses the RadFrac module;
5) The pump uses the PUMP module;
6) The splitter uses the FAPLIT module.
During the model simulation process, the material flow is connected to each other according to the functions of different unit modules, and the process is executed according to the production process of oxygen. During the simulation, the equipment parameters were set according to the design values, where the top pressure of the distillation tower was set to 0.558 MPa, the bottom pressure was set to 0.564 MPa, the top temperature was set to -177.62 ℃, the bottom temperature was set to -173.
65 ℃, and the number of plates was 49. After simulation analysis, the results are shown in Table 1.

 

Simulation results of process model of air separation unit
Project Design indicators Simulation indicators
Dirty liquid nitrogen flow into upper tower/(kmol/h) 4000 4007
Liquid air flow into upper tower/(kmol/h) 5000 5000
Liquid nitrogen flow into upper tower/(kmol/h) 4000 4000
Liquid air purity of lower tower x(O2)/% 37 36.1
Dirty nitrogen purity of upper tower x(Nz)1% 90 89.87
Nitrogen flow out of cold box/(kmol/h) 2350 2350
Pressure at the bottom of upper tower/MPa 0.14 0.14
Pressure at the top of lower tower/MPa 0.56 0.558
Nitrogen product output/(kmol/h) 2400 2400
Medium pressure liquid nitrogen output/(kmol/h) 2940 2 924.38
Low pressure liquid nitrogen output/(kmol/h) 1360 1336.58

 

From the simulation results of the model in Table 1, it can be seen that the various indicators of the model are basically consistent with the design indicators of the cryogenic air separation unit. The difference between the liquid air purity of the lower tower and the design value is 0.9%, and the fluctuation of the simulation value is within the allowable range. The simulated nitrogen output is also close to the design value, and the error is within the allowable range. It can be seen that the model established this time can be used for process optimization verification analysis1.

 

2 Process optimization analysis


In the gas separation process of the cryogenic air separation unit, the lower tower of the distillation tower is the core equipment. According to the research on the equipment and the auxiliary theoretical analysis, the purpose of energy saving and consumption reduction can be achieved by changing the process parameters of the lower tower of the distillation tower. This time, the Aspen Plus sensitivity module was used to conduct a detailed analysis of the different process parameters of the lower tower of the distillation tower, and the optimal process operation plan was obtained.
2.1
Relationship between feed position and heat load
During the simulation process, other parameters were kept unchanged, the feed position was changed, and the heat load at the top of the tower changed. The results are shown in Figure 1. As shown in Figure 1, when the other parameters remain unchanged, by changing the feed position of the lower tower of the distillation tower, the heat load at the top of the tower will gradually decrease until the feed position is set to the 33rd tower plate, and the heat load at the top of the tower basically remains constant. It can be seen that the 33rd tower plate is the best feed position.
2.2 Relationship between feed flow rate and nitrogen production and purity By changing the feed flow rate of the lower tower and keeping other parameters unchanged, the changes in the production and purity of liquid nitrogen at the top of the distillation tower are shown in Figure 2. As shown in Figure 2, with the increase of the feed flow rate of the lower tower, the production of liquid nitrogen is gradually increasing, but at the same time the purity is decreasing, which is also consistent with the theory. As shown in the figure, when the feed flow rate of the lower tower is below 804 kmol/h, the purity of liquid nitrogen is above 99.999%, which meets the gas demand of the metallurgical industry. At this time, the output is 3,230 kmol/h, which is quite different from the initial flow feed flow rate of 761.3 kmol/h and the liquid nitrogen output of 3,187.38 kmol/h. It can be seen that the feed flow rate should be controlled to 804 kmol/h, which can increase the output while ensuring the purity of nitrogen.
2.3 Effect of temperature on products
Keeping other parameters unchanged, the change of liquid nitrogen flow rate is checked by changing the temperature, and the results are shown in Figure 3. As shown in Figure 3, the liquid nitrogen flow rate is positively correlated with the feed temperature, but with the change of temperature, the change of liquid nitrogen output is relatively small, and it has little effect on the actual production results. Therefore, it is more appropriate to set the feed temperature to -173 ℃. If the temperature is too high, it will affect the subsequent air separation device to separate oxygen, argon, etc.; if the temperature is too low, the energy consumption is relatively large, which does not meet the purpose of energy saving and consumption reduction.


3 Practical application of process optimization scheme


The gas produced by a certain factory is mainly sold to metallurgical enterprises, and the nitrogen produced is directly supplied to metallurgical enterprises as a protective gas. In recent years, with the decline of the market economy and the increase of labor costs, the economic benefits of the factory have become lower and lower. Under such circumstances, the factory proposed to change the production process situation to reduce the kinetic energy consumption of the equipment and thus increase economic benefits. After research and analysis, the factory carried out process improvements in March 2022. The improvement plan is: the distillation tower pressure is set to 0.56 MPa, the lower tower feed temperature is set to -173 ℃, the lower tower feed amount is adjusted to 804 kmol/h, and the feed position is set at the 33rd tower plate. Due to process improvement, the heat load of the distillation tower will be reduced, so the air handling capacity of the cryogenic air separation unit can be appropriately increased, thereby increasing the output of nitrogen. Therefore, during the process improvement, the feed flow rate of the air compression system is changed at the same time, and the application effect of the cryogenic air separation unit is analyzed under different loads. The verification cycle of each load is 10 days, and the production situation is shown in Table 2.
It can be seen from Table 2 that after the process optimization, the maximum load of the variable working condition can reach 120% of the original load, and the output of nitrogen and liquid nitrogen is increased in this case. Moreover, at 120% load, the heat load at the top of the distillation tower changed from -8.29 MW to -7.67 MW, saving 7.48% of energy. After analyzing the power of the equipment, it can be seen that the power of the equipment under 120% load is reduced by 132 kW·h. The industrial electricity cost in the area where the factory is located is 0.69 yuan (/ kW·h). According to the equipment operation for 330 days, the annual power cost can be saved by 721,000 yuan. In terms of product output, after process optimization, the nitrogen output increased by 450.54 kmol/h, the medium-pressure liquid nitrogen output increased by 625.48 kmol/h, and the low-pressure liquid nitrogen output increased by 281.34 kmol/h. After calculation, the profit can be increased by 3.876 million yuan throughout the year. It can be seen that the process improvement can create 4.597 million yuan of income for the enterprise throughout the year.

 

 

 

Send Inquiry